Expression and Purification of HPV Proteins for Early Detection of Head and Neck Cancer
Description
Recent studies have shown that human papillomavirus (HPV) plays a role in development of cancers, one of which is head and neck cancer. There is strong and consistent molecular evidence demonstrating that human papillomavirus (HPV) is an etiological cause of these oropharyngeal cancers. Despite the introduction of HPV vaccines, there is still an increase in human papillomavirus associated OPC (HPVOPC) and it is expected that the incidence of head and neck cancer, specifically oropharyngeal cancer (OPC) will increase. The aim of this study is to utilize human papillomavirus (HPV) seropositivity for rapid detection of HPV early specific antigen-antibodies using a lateral flow assay.
Human papillomavirus (HPV) 16 proteins of interest, E7, E6 and CE2 were expressed and purified in E. coli for detection of specific antibodies using lateral flow assay because viral and host factors impact the serologic responses to HPV early antigens in HPV-positive oropharyngeal cancer. 17 samples and 5 controls with already known antibody reactivity from ELISA analysis were selected for HPV serologic responses. The lateral flow strip was evaluated for its color band intensity using Image J software. Peak area was used to quantify the color intensity of the lateral flow strip. Out of the 17 samples, 11 (64.7%) showed high antibody levels to E7, 12 (70.6%) showed high Ab levels to E6 and 6 (35.3%) showed high Ab levels to CE2. Correlation coefficient between antibody detection by sight and ELISA for E7, CE2 and E6 were 0.6614, 0.4845 and 0.2372 respectively and correlation coefficient between lateral flow assay and ELISA for E7, CE2 and E6 were 0.3480, 0.1716 and 0.1644 respectively. This further proves patients or samples with HPV 16 oropharyngeal cancer have detectable antibodies to early E7, E6 and E2 proteins, which are potential biomarkers for HPV-associated oropharyngeal cancer.
Human papillomavirus (HPV) 16 proteins of interest, E7, E6 and CE2 were expressed and purified in E. coli for detection of specific antibodies using lateral flow assay because viral and host factors impact the serologic responses to HPV early antigens in HPV-positive oropharyngeal cancer. 17 samples and 5 controls with already known antibody reactivity from ELISA analysis were selected for HPV serologic responses. The lateral flow strip was evaluated for its color band intensity using Image J software. Peak area was used to quantify the color intensity of the lateral flow strip. Out of the 17 samples, 11 (64.7%) showed high antibody levels to E7, 12 (70.6%) showed high Ab levels to E6 and 6 (35.3%) showed high Ab levels to CE2. Correlation coefficient between antibody detection by sight and ELISA for E7, CE2 and E6 were 0.6614, 0.4845 and 0.2372 respectively and correlation coefficient between lateral flow assay and ELISA for E7, CE2 and E6 were 0.3480, 0.1716 and 0.1644 respectively. This further proves patients or samples with HPV 16 oropharyngeal cancer have detectable antibodies to early E7, E6 and E2 proteins, which are potential biomarkers for HPV-associated oropharyngeal cancer.
Date Created
The date the item was original created (prior to any relationship with the ASU Digital Repositories.)
2019
Agent
- Author (aut): Ladipo, Evelyn
- Thesis advisor (ths): Anderson, Karen S
- Committee member: Hogue, Brenda G
- Committee member: Hou, Ching-Wen
- Publisher (pbl): Arizona State University