Development and Evaluation of a Laboratory Water Pump Simulation with Measurement Uncertainty for Enhanced Learning

189306-Thumbnail Image.png
Description
Expedited by the ongoing effects of the Covid-19 pandemic and the expanding portfolio of Arizona State University's online degree programs, this study undertakes the task of enriching the “Experimental Mechanical Engineering” course within ASU's online Bachelor of Mechanical Engineering curriculum.

Expedited by the ongoing effects of the Covid-19 pandemic and the expanding portfolio of Arizona State University's online degree programs, this study undertakes the task of enriching the “Experimental Mechanical Engineering” course within ASU's online Bachelor of Mechanical Engineering curriculum. This thesis outlines the development of simulations accurately mirroring the characteristics and functionalities of water pump laboratory experiments, which previously necessitated on-site, group-based participation. The goal is for these simulations to serve as digital twins of the original equipment, allowing students to examine fundamental mechanical principles like the Bernoulli equation and Affinity Laws in a virtual, yet realistic setting. Furthermore, the simulations are designed to accommodate uncertainty calculations, replicating the instrument error (i.e., bias and precision uncertainty) inherent in the original water pump units. The methodology of this simulation design predominantly involves the use of MATLAB SimScape, chosen for its configurability and simplicity, with modifications made to match the original experiment data. Then, subsequent analysis of results between the simulation and experiment is conducted to facilitate the validation process. After executing the full laboratory procedure using the simulations, they displayed rapid operation and produced results that remained within boundaries of experimental uncertainty, it also faces several challenges, such as the inability to simulate the pump cavitation effect and the lack of animation. Future research should focus on addressing these limitations, thereby enhancing the model’s precision and extending its functionality to provide better visualization capabilities and exploration of pump cavitation effects. Furthermore, students’ feedback needs to be collected, since it is essential to assess and validate the effectiveness of this instructional approach.
Date Created
2023
Agent

Fabrication of Solid Oxide Fuel Cells and the Effects of Linear Siloxane Deposition on Cell Performance

168383-Thumbnail Image.png
Description
Biogas’s potential as a renewable fuel source has been an area of increased research in recent years. One issue preventing wide-spread use of biogas as a fuel is the trace amounts of impurities that damage fuel-burning equipment by depositing silicon,

Biogas’s potential as a renewable fuel source has been an area of increased research in recent years. One issue preventing wide-spread use of biogas as a fuel is the trace amounts of impurities that damage fuel-burning equipment by depositing silicon, sulfur, calcium and other elements on their surface. This study aims to analyze the effects of a high concentration of L4 linear siloxane on solid oxide fuel cell performance until failure occurs. L4 siloxane has not been extensively researched previously, and this investigation aims to provide new data to support similar, though slower, degradation compared to D4, D5 and other siloxanes in solid oxide fuel cells. The experiments were conducted inside a furnace heated to 800℃ with an Ni-YSZ-supported (Nickel-yttria-stabilized zirconia) fuel cell. A fuel source with a flow rate of 20 mL/min of hydrogen gas, 10 mL/min of nitrogen gas and 0.15 mL/min of L4 siloxane was used. Air was supplied to the cathode. The effects of siloxane deposition on cell voltage and power density degradation and resistance increase were studied by using techniques like the current-voltage method, electrochemical impedance spectroscopy, and gas chromatography. The results of the experiment after reduction show roughly constant degradation of 8.35 mV/hr, followed after approximately 8 hours by an increasing degradation until cell failure of 130.45 mV/hr. The initial degradation and stagnation match previous research in siloxane deposition on SOFCs, but the sharp decline to failure does not. A mechanism for solid oxide fuel cell failure is proposed based on the data.
Date Created
2021
Agent