Near-infrared Contrast Agents for Cell Type Identification and Detection Utilizing Photoacoustics

168649-Thumbnail Image.png
Description
The imaging and detection of specific cell types deep in biological tissue is critical for the diagnosis of cancer and the study of biological phenomena. Current high-resolution optical imaging techniques are depth limited due to the high degree of optical

The imaging and detection of specific cell types deep in biological tissue is critical for the diagnosis of cancer and the study of biological phenomena. Current high-resolution optical imaging techniques are depth limited due to the high degree of optical scattering that occurs in tissues. To address these limitations, photoacoustic (PA) techniques have emerged as noninvasive methods for the imaging and detection of specific biological structures at extended depths in vivo. In addition, near-infrared (NIR) contrast agents have further increased the depth at which PA imaging can be achieved in biological tissues. The goal of this research is to combine novel PA imaging and NIR labeling strategies for the diagnosis of disease and for the detection of neuronal subtypes. Central Hypothesis: Utilizing custom-designed PA systems and NIR labeling techniques will enable the detection of specific cell types in vitro and in mammalian brain slices. Work presented in this dissertation addresses the following: (Chapter 2): The custom photoacoustic flow cytometry system combined with NIR absorbing copper sulfide nanoparticles for the detection of ovarian circulating tumor cells (CTCs) at physiologically relevant concentrations. Results obtained from this Chapter provide a unique tool for the future detection of ovarian CTCs in patient samples at the point of care. (Chapter 3): The custom photoacoustic microscopy (PAM) system can detect genetically encoded near-infrared fluorescent proteins (iRFPs) in cells in vitro. Results obtained from this Chapter can significantly increase the depth at which neurons and cellular processes can be targeted and imaged in vitro. (Chapter 4): Utilizing the Cre/lox recombination system with AAV vectors will enable selective tagging of dopaminergic neurons with iRFP for detection in brain slices using PAM. Thus, providing a new means of increasing the depth at which neuronal subtypes can be imaged and detected in the mammalian brain. Significance: Knowledge gained from this research could have significant impacts on the PA detection of ovarian cancer and extend the depth at which neuronal subtypes are imaged in the mammalian brain.
Date Created
2022
Agent

Imaging and Targeting with Optics and Acoustics

161721-Thumbnail Image.png
Description
This thesis describes the development, characterization, and application of new biomedical technologies developed around the photoacoustic effect. The photoacoustic effect is defined as optical absorption-based generation of ultrasound and provides the foundation for a unique method of imaging and molecular

This thesis describes the development, characterization, and application of new biomedical technologies developed around the photoacoustic effect. The photoacoustic effect is defined as optical absorption-based generation of ultrasound and provides the foundation for a unique method of imaging and molecular detection. The range of applications of the photoacoustic effect have not yet been fully explored. Photoacoustic endoscopy (PAE) has emerged as a minimally invasive tool for imaging internal organs and tissues. One of the main themes of this dissertation involves the first reported dual-intrauterine photoacoustic and ultrasound deep-tissue imaging endoscope. This device was designed to enable physicians at the point-of-care to better elucidate overall gynecological health, by imaging the lining of the human uterus. Intrauterine photoacoustic endoscopy is made possible due to the small diameter of the endoscope (3mm), which allows for complete, 360-degree organ analysis from within the uterine cavity. In certain biomedical applications, however, further minimization is necessary. Sufficiently small diameter endoscopes may allow for the possibility of applying PAE in new areas. To further miniaturize the diameter of our endoscopes, alternative imaging probe designs were investigated. The proposed PAE architecture utilizes a hollow optical waveguide to allow for concentric guiding of both light and sound. This enables imaging depths of up to several millimeters into animal tissue while maintaining an outer diameter of roughly 1mm. In the final focus of this dissertation, these waveguides are further investigated for use in micropipette electrodes, common in the field of single cell electrophysiology. Pulsed light is coupled with these electrodes providing real-time photoacoustic feedback, useful in navigation towards intended targets. Lastly, fluorescence can be generated and collected at the micropipette aperture by utilizing an intra-electrode tapered optical fiber. This allows for a targeted robotic approach to labeled neurons that is independent of microscopy.
Date Created
2021
Agent

Modeling, Design, Fabrication, and Characterization of a Highly Sensitive Fluorescence-based Detection Platform for Point-of-Care Applications

156930-Thumbnail Image.png
Description
Over the past several decades, there has been a growing interest in the use of fluorescent probes in low-cost diagnostic devices for resource-limited environments. This dissertation details the design, development, and deployment of an inexpensive, multiplexed, and quantitative, fluorescence-based lateral

Over the past several decades, there has been a growing interest in the use of fluorescent probes in low-cost diagnostic devices for resource-limited environments. This dissertation details the design, development, and deployment of an inexpensive, multiplexed, and quantitative, fluorescence-based lateral flow immunoassay platform, in light of the specific constraints associated with resource-limited settings.

This effort grew out of the need to develop a highly sensitive, field-deployable platform to be used as a primary screening and early detection tool for serologic biomarkers for the high-risk human papillomavirus (hrHPV) infection. A hrHPV infection is a precursor for developing high-grade cervical intraepithelial neoplasia (CIN 2/3+). Early detection requires high sensitivity and a low limit-of-detection (LOD). To this end, the developed platform (DxArray) takes advantage of the specificity of immunoassays and the selectivity of fluorescence for early disease detection. The long term goal is to improve the quality of life for several hundred million women globally, at risk of being infected with hrHPV.

The developed platform uses fluorescent labels over the gold-standard colorimetric labels in a compact, high-sensitivity lateral flow assay configuration. It is also compatible with POC settings as it substitutes expensive and bulky light sources for LEDs, low-light CMOS cameras, and photomultiplier tubes for photodiodes, in a transillumination architecture, and eliminates the need for expensive focusing/transfer optics. The platform uses high-quality interference filters at less than $1 each, enabling a rugged and robust design suitable for field use.

The limit of detection (LOD) of the developed platform is within an order of magnitude of centralized laboratory diagnostic instruments. It enhances the LOD of absorbance or reflectometric and visual readout lateral flow assays by 2 - 3 orders of magnitude. This system could be applied toward any chemical or bioanalytical procedure that requires a high performance at low-cost.

The knowledge and techniques developed in this effort is relevant to the community of researchers and industry developers looking to deploy inexpensive, quantitative, and highly sensitive diagnostic devices to resource-limited settings.
Date Created
2018
Agent