Building-Integrated Carbon Capture: A Study on the Design and Potential of Carbon Emission Offsets from Buildings

161509-Thumbnail Image.png
Description
Building-integrated carbon-capture (BICC) is an envisioned mechanism capable of absorbing carbon dioxide (CO2) from the air to be stored and then converted into useful carbon-based materials without negatively impacting the environment. This dissertation builds on the authors' previous work, in

Building-integrated carbon-capture (BICC) is an envisioned mechanism capable of absorbing carbon dioxide (CO2) from the air to be stored and then converted into useful carbon-based materials without negatively impacting the environment. This dissertation builds on the authors' previous work, in which building façades were treated as artificial leaves capable of providing shade to lower solar heat gain, while simultaneously capturing CO2 through the air filters attached to the building façades by attempting a different approach capable of capturing CO2 within buildings. This dissertation presents the author’s work on BICC, where buildings are envisioned as CO2 reservoirs or vacuums, into which mechanical systems introduce fresh air, and through human activities, the air within the building becomes enriched with CO2 before being pushed out back to the outer environment. The design of a carbon-capture mechanism will take advantage of the ventilation side of existing HVAC systems, through which BICC captures CO2 from the exhaust-enriched CO2 air. BICC will utilize existing opportunities and components within buildings represented in the high CO2 concentration in buildings, ventilation guidelines, mechanical equipment represented in air handling unit and air duct network, in addition to natural gas grid connectivity. BICC will capture CO2 through buildings' mechanical system, and the captured CO2 would then be converted into renewable methane to be injected into the existing natural gas pipeline network. This dissertation will investigate the potential of BICC to offset carbon emissions from multiple commercial building types and will present a utilization strategy for the captured carbon.
Date Created
2021
Agent

The effect of floor to area ratio parameter on net zero commercial buildings located in Phoenix, Arizona

Description
The building sector is one of the main energy consumers within the USA. Energy demand by this sector continues to increase because new buildings are being constructed faster than older ones are retired. Increase in energy demand, in addition to

The building sector is one of the main energy consumers within the USA. Energy demand by this sector continues to increase because new buildings are being constructed faster than older ones are retired. Increase in energy demand, in addition to a number of other factors such as the finite nature of fossil fuels, population growth, building impact on global climate change, and energy insecurity and independence has led to the increase in awareness towards conservation through the design of energy efficient buildings. Net Zero Energy Building (NZEB), a highly efficient building that produces as much renewable energy as it consumes annually, provides an effective solution to this global concern. The intent of this thesis is to investigate the relationship of an important factor that has a direct impact on NZEB: Floor / Area Ratio (FAR). Investigating this relationship will help to answer a very important question in establishing NZEB in hot-arid climates such as Phoenix, Arizona. The question this thesis presents is: “How big can a building be and still be Net Zero?” When does this concept start to flip and buildings become unable to generate the required renewable energy to achieve energy balance? The investigation process starts with the analysis of a local NZEB, DPR Construction Office, to evaluate the potential increase in building footprint and FAR with respect to the current annual Energy Use Intensity (EUI). Through the detailed analysis of the local NZEB, in addition to the knowledge gained through research, this thesis will offer an FAR calculator tool that can be used by design teams to help assess the net zero potential of their project. The tool analyzes a number of elements within the project such as total building footprint, available surface area for photovoltaic (PV) installation, outdoor circulation and landscape area, parking area and potential parking spots, potential building area in regards to FAR, number of floors based on the building footprint, FAR, required area for photovoltaic installation, photovoltaic system size, and annual energy production, in addition to the maximum potential FAR their project can reach and still be Net Zero.
Date Created
2016
Agent