Study of collocated sources of air pollution and the potential for circumventing regulatory major source permitting requirements near Sun City, Arizona

150264-Thumbnail Image.png
Description
The following research is a regulatory and emissions analysis of collocated sources of air pollution as they relate to the definition of "major, stationary, sources", if their emissions were amalgamated. The emitting sources chosen for this study are seven facilities

The following research is a regulatory and emissions analysis of collocated sources of air pollution as they relate to the definition of "major, stationary, sources", if their emissions were amalgamated. The emitting sources chosen for this study are seven facilities located in a single, aggregate mining pit, along the Aqua Fria riverbed in Sun City, Arizona. The sources in question consist of Rock Crushing and Screening plants, Hot Mix Asphalt plants, and Concrete Batch plants. Generally, individual facilities with emissions of a criteria air pollutant over 100 tons per year or 70 tons per year for PM10 in the Maricopa County non-attainment area would be required to operate under a different permitting regime than those with emissions less than stated above. In addition, facility's that emit over 25 tons per year or 150 pounds per hour of NOx would trigger Maricopa County Best Available Control Technology (BACT) and would be required to install more stringent pollution controls. However, in order to circumvent the more stringent permitting requirements, some facilities have "collocated" in order to escape having their emissions calculated as single source, while operating as a single, production entity. The results of this study indicate that the sources analyzed do not collectively emit major source levels of emissions; however, they do trigger year and daily BACT for NOx. It was also discovered that lack of grid power contributes to the use of generators, which is the main source of emissions. Therefore, if grid electricity was introduced in outlying areas of Maricopa County, facilities could significantly reduce the use of generator power; thereby, reducing pollutants associated with generator use.
Date Created
2011
Agent

The potential of coastal marine filtration as a feedstock source for biodiesel

150253-Thumbnail Image.png
Description
Second-generation biofuel feedstocks are currently grown in land-based systems that use valuable resources like water, electricity and fertilizer. This study investigates the potential of near-shore marine (ocean) seawater filtration as a source of planktonic biomass for biofuel production. Mixed marine

Second-generation biofuel feedstocks are currently grown in land-based systems that use valuable resources like water, electricity and fertilizer. This study investigates the potential of near-shore marine (ocean) seawater filtration as a source of planktonic biomass for biofuel production. Mixed marine organisms in the size range of 20µm to 500µm were isolated from the University of California, Santa Barbara (UCSB) seawater filtration system during weekly backwash events between the months of April and August, 2011. The quantity of organic material produced was determined by sample combustion and calculation of ash-free dry weights. Qualitative investigation required density gradient separation with the heavy liquid sodium metatungstate followed by direct transesterification and gas chromatography with mass spectrometry (GC-MS) of the fatty acid methyl esters (FAME) produced. A maximum of 0.083g/L of dried organic material was produced in a single backwash event and a study average of 0.036g/L was calculated. This equates to an average weekly value of 7,674.75g of dried organic material produced from the filtration of approximately 24,417,792 liters of seawater. Temporal variations were limited. Organic quantities decreased over the course of the study. Bio-fouling effects from mussel overgrowth inexplicably increased production values when compared to un-fouled seawater supply lines. FAMEs (biodiesel) averaged 0.004% of the dried organic material with 0.36ml of biodiesel produced per week, on average. C16:0 and C22:6n3 fatty acids comprised the majority of the fatty acids in the samples. Saturated fatty acids made up 30.71% to 44.09% and unsaturated forms comprised 55.90% to 66.32% of the total chemical composition. Both quantities and qualities of organics and FAMEs were unrealistic for use as biodiesel but sample size limitations, system design, geographic and temporal factors may have impacted study results.
Date Created
2011
Agent

Preliminary concepts for developing childhood education in emergency preparedness

150034-Thumbnail Image.png
Description
Being properly prepared is one of the keys to surviving an emergency or a disaster. In order to be prepared, people need appropriate education in preparedness, which includes elements of prevention, and planning. There is a definite need to better

Being properly prepared is one of the keys to surviving an emergency or a disaster. In order to be prepared, people need appropriate education in preparedness, which includes elements of prevention, and planning. There is a definite need to better prepare our nation's citizens in order for them to safely respond in times of a disaster. It also seems likely that the earlier concepts and skills are learned, the easier those concepts and skills would be to remember and the more proficient one would become in implementing them. Therefore, it seems appropriate to teach emergency preparedness concepts and skills early on in the educational process. This means that significant efforts need to be directed toward learning, what impediments currently exist, what is helpful, and how preparedness concepts and skills can be taught to our children. A survey was distributed to third, fourth, and fifth grade teachers, asking them questions about emergency preparedness lessons in the classroom. Results indicated that the majority of teachers would be willing to teach emergency preparedness if the curriculum met current academic standards and they were given adequate resources to teach this subject. This study provides ideas, concepts and motivation for teachers to use in a cross-curricular approach to teaching emergency preparedness in the classroom. This is accomplished by presenting examples of newly developed curriculum/lesson plans that meet state academic standards, based on the current Community Emergency Response Team program and on children's fiction literature for the appropriate age group. A list of literature that could be used in this development is also provided in this study.
Date Created
2011
Agent

Fabrication and evaluation of hematite modified granular activated carbon (GAC) media for arsenic removal from groundwater

149765-Thumbnail Image.png
Description
The goal of the study was twofold: (i) to investigate the synthesis of hematite-impregnated granular activated carbon (Fe-GAC) by hydrolysis of Fe (III) and (ii) to assess the effectiveness of the fabricated media in removal of arsenic from water. Fe-GAC

The goal of the study was twofold: (i) to investigate the synthesis of hematite-impregnated granular activated carbon (Fe-GAC) by hydrolysis of Fe (III) and (ii) to assess the effectiveness of the fabricated media in removal of arsenic from water. Fe-GAC was synthesized by hydrolysis of Fe(III) salts under two Fe (III) initial dosages (0.5M and 2M) and two hydrolysis periods (24 hrs and 72 hrs). The iron content of the fabricated Fe-GAC media ranged from 0.9% to 4.4% Fe/g of the dry media. Pseudo-equilibrium batch test data at pH = 7.7±0.2 in 1mM NaHCO3 buffered ultrapure water and challenge groundwater representative of the Arizona Mexico border region were fitted to a Freundlich isotherm model. The findings suggested that the arsenic adsorption capacity of the metal (hydr)oxide modified GAC media is primarily controlled by the surface area of the media, while the metal content exhibited lesser effect. The adsorption capacity of the media in the model Mexican groundwater matrix was significantly lower for all adsorbent media. Continuous flow short bed adsorber tests (SBA) demonstrated that the adsorption capacity for arsenic in the challenge groundwater was reduced by a factor of 3 to 4 as a result of the mass transport effects. When compared on metal basis, the iron (hydr)oxide modified media performed comparably well as existing commercial media for treatment of arsenic. On dry mass basis, the fabricated media in this study removed less arsenic than their commercial counterparts because the metal content of the commercial media was significantly higher.
Date Created
2011
Agent

Government incentives and how they encourage manufacturing facilities to adopt environmental management systems: a look at the efficiency of policy tools

149706-Thumbnail Image.png
Description
Traditional methods of environmental regulation and enforcement have been questioned over the last decade. Due to the number of environmental regulations, and subsequent cost of enforcement, governments have begun to incentivize the adoption of environmental management systems (EMSs). These

Traditional methods of environmental regulation and enforcement have been questioned over the last decade. Due to the number of environmental regulations, and subsequent cost of enforcement, governments have begun to incentivize the adoption of environmental management systems (EMSs). These management systems encourage companies to better manage their environmental performance voluntarily. It is the purpose of this study to list the types of government incentives that have been used and categorize them into three groups based off of their characteristics. Ten incentive types were identified and put into three categories; (a) reducing the barriers to EMS adoption; (b) enhancing benefits derived from EMS adoption, and (c) rewarding EMS implementers with reduced enforcement. The research shows that each category of incentives encourages different manufacturing facilities to adopt EMSs. Using data from previously conducted case studies and surveys to determine what type of manufacturing facilities are affected, this study finds that government incentives have been shown to have a measurable impact on the decision makers of manufacturing facilities to adopt an EMS. The study concludes that a combination of traditional environmental regulation used with targeted incentives provide the most efficient use of resources by governments.
Date Created
2011
Agent

Maricopa County particulate matter source study

149661-Thumbnail Image.png
Description
Maricopa County has exceeded the 24 hour National Ambient Air Quality Standard (NAAQS) for Particulate Matter 10 micrometers in diameter or smaller (PM-10) of 150 micrograms per meter cubed (μg/m3) since 1990. Construction and construction related activities have been recognized

Maricopa County has exceeded the 24 hour National Ambient Air Quality Standard (NAAQS) for Particulate Matter 10 micrometers in diameter or smaller (PM-10) of 150 micrograms per meter cubed (μg/m3) since 1990. Construction and construction related activities have been recognized as the highest contributors to high PM-10 levels. An analysis of days exceeding 150 μg/m3 for four of Maricopa County‟s monitors that most frequently exceed this level during the years 2007, 2008, and 2009 has been performed. Noted contributors to PM-10 levels have been identified in the study, including earthmoving permits, stationary source permits, vacant lots, and agriculture on two mile radius maps around each monitor. PM-10 levels and wind speeds for each date exceeding 225 μg/m3 were reviewed to find specific weather or anthropogenic sources for the high PM-10 levels. Weather patterns for days where multiple monitors exceed 150 μg/m3 were reviewed to find correlations between daily weather and high PM-10 levels. It was found that areas with more earthmoving permits had fewer days exceeding 150 μg/m3 than areas with more stationary permits, vacant lots, or agriculture. The Higley and Buckeye monitors showed increases in PM-10 levels when winds came from areas covered by agricultural land. West 43rd Avenue and Durango monitors saw PM-10 rise when the winds came in over large stationary sources, like aggregate plants. A correlation between weather events and PM-10 exceedances was also found on multiple monitors for dates both in 2007, and 2009.
Date Created
2011
Agent

An analysis of the impacts and non-attainment risks of the revised sulfur dioxide national ambient air quality standard on the Toledo core based statistical area using the American Meteorological Society-Environmental Protection Agency regulatory model

149657-Thumbnail Image.png
Description
The Toledo Core Based Statistical Area (CBSA) presents an interesting case study for the new sulfur dioxide (SO2) one hour standard. Since no SO2 monitor within 75 miles to estimate the attainment status of the area, American Meteorological Society/Environmental Protection

The Toledo Core Based Statistical Area (CBSA) presents an interesting case study for the new sulfur dioxide (SO2) one hour standard. Since no SO2 monitor within 75 miles to estimate the attainment status of the area, American Meteorological Society/Environmental Protection Agency Regulatory Model (AERMOD) was used in this study to predict potential problems associated with the newly revised standard. The Toledo CBSA is home to two oil refineries, a glass making industry, several coal fired lime kilns, and a sulfuric acid regeneration plant, The CBSA 3 has coal fired power plants within a 30 mile radius of its center. Additionally, Toledo is a major Great Lakes shipping port visited by both lake and ocean going vessels. As a transportation hub, the area is also traversed by several rail lines which feed four rail switching yards. Impacts of older generation freighters, or "steamers", utilizing high sulfur "Bunker C" fuel oil in the area is also an issue. With the unique challenges presented by an SO2 one hour standard, this study attempted to estimate potential problem areas in advance of any monitoring data being gathered. Based on the publicly available data as inputs, it appears that a significant risk of non-attainment may exist in the Toledo CBSA. However, future on-the-books controls and currently proposed regulatory actions appear to drive the risk below significance by 2015. Any designation as non-attainment should be self-correcting and without need for controls other than those used in these models. The outcomes of this screening study are intended for use as a basis for assessments for other mid-sized, industrial areas without SO2 monitors. The results may also be utilized by industries and planning groups within the Toledo CBSA to address potential issues in advance of monitoring system deployment to lower the risk of attaining long term or perpetual non-attainment status.
Date Created
2011
Agent

Solar water disinfection

149532-Thumbnail Image.png
Description
Water quality is a severe problem throughout the world. Much available water is contaminated by pathogenic microbes. This project reviews the traditional process of solar water disinfection in bottles (SODIS), discusses experiments conducted with SODIS bottles modified to thermally enhance

Water quality is a severe problem throughout the world. Much available water is contaminated by pathogenic microbes. This project reviews the traditional process of solar water disinfection in bottles (SODIS), discusses experiments conducted with SODIS bottles modified to thermally enhance the process, analyzes experimental data for modified SODIS containers, and suggests ways that by which the traditional process can be improved. Traditional SODIS is currently used in many rural parts of developing countries to disinfect water. The process uses ultraviolet rays and thermal effects to inactivate microorganisms that tend to cause diarrheal disease. If a sufficiently high temperature is attained to reach a synergistic UV-thermal effect range, the process of SODIS is about three times faster. However, many factors can inhibit attainment of sufficient heating of water in SODIS bottles in practice. By modifying the bottles to enhance effectiveness of sunlight in increasing the temperature of the water, SODIS can be more effective. In this research, a series of experiments were conducted over a period of four months and15 days at Arizona State University Polytechnic campus in Mesa, Arizona, U.S.A. Four different types of inexpensive materials (black paint, white paint, foam insulation, and aluminized mylar) were used individually or in combination in seven different modified configurations to assess the potential of the modifications to increase the temperatures of water inside 2-liter PET bottles. Experiments were run in triplicate. Temperatures inside the bottles, along with yard temperature, were recorded over time. Graphs were plotted for each set of experiments. The results of these experiment show that several types of modifications increased water temperature during exposure to sunlight. Water in bottles with black paint and foam insulation on the back side attained the highest temperatures, approximately 8-10 degrees Celsius above temperatures attained in plain bottles. The results of these experiments show how several inexpensive, easily obtained materials can significantly enhance the SODIS process.
Date Created
2011
Agent

A Six Sigma-based approach to leadership in energy and environmental design for existing buildings: operations and maintenance

149458-Thumbnail Image.png
Description
With increasing interest in sustainability and green building, organizations are implementing programs such as Leadership in Energy and Environmental Design for Existing Buildings: Operations and Maintenance (LEED-EB) in order to focus corporate sustainability goals on the operations of a facility

With increasing interest in sustainability and green building, organizations are implementing programs such as Leadership in Energy and Environmental Design for Existing Buildings: Operations and Maintenance (LEED-EB) in order to focus corporate sustainability goals on the operations of a facility and the practices of the building occupants. Green building programs help reduce the impact of a facility and bring about several environmental benefits including but not limited to energy conservation, water conservation and material conservation. In addition to various environmental benefits, green building programs can help companies become more efficient. The problem is that organizations are not always successful in their pursuits to achieve sustainability goals. It frequently take years to implement a program, and in many cases the goals for sustainability never come to fruition, when in the mean time resources are wasted, money is spent needlessly and opportunities are lost forever. This thesis addresses how the Six Sigma methodologies used by so many to implement change in their organizations could be applied to the LEED-EB program to help companies achieve sustainability results. A qualitative analysis of the Six Sigma methodologies was performed to determine if and how a LEED-EB program might utilize such methods. The two programs were found to be compatible and several areas for improvements to implementing a LEED-EB program were identified.
Date Created
2010
Agent

Development of a monitoring and maintenance program for residential wells used for groundwater abstraction in Lagos State, Nigeria

Description
In rural and urban areas of Nigeria, dependence on groundwater is increasing since the population is growing and high quality, treated municipal water is scarce. Municipal drinking water is often compromised because of old and leaking distribution pipes. About 58%

In rural and urban areas of Nigeria, dependence on groundwater is increasing since the population is growing and high quality, treated municipal water is scarce. Municipal drinking water is often compromised because of old and leaking distribution pipes. About 58% of the water consumed in Lagos State, Nigeria, comes from residential wells. However, a majority of residential wells are shallow wells that are constructed relatively close to septic tanks or pit latrines and are therefore subject to contamination. In certain parts of Africa, there is high potential of severe epidemic if water quality is not improved. With increasing reliance on groundwater, a need exists to monitor the quality of groundwater. This thesis develops a plan for a monitoring program for residential wells in Lagos State, Nigeria. The program focuses on ways by which owners can maintain reasonably good water quality, and on the role of government in implementing water quality requirements. In addition, this thesis describes a survey conducted in various areas of Lagos State to assess community awareness of the importance of groundwater quality and its impact on individuals and the community at large. The survey shows that 30% to 40% of the households have located their wells and septic tanks in the same general area. Various templates have been created to help the staff of a future monitoring program team to effectively gather information during site characterization. A "Questions and Answers" leaflet has been developed to educate citizens about the need for monitoring residential wells. 
Date Created
2010
Agent