Description

Background: The quantification of the relationships between walking and health requires that walking is measured accurately. We correlated different measures of step accumulation to body size, overall physical activity level, and glucose regulation.

Methods: Participants were 25 men and 25 women American Indians

Background: The quantification of the relationships between walking and health requires that walking is measured accurately. We correlated different measures of step accumulation to body size, overall physical activity level, and glucose regulation.

Methods: Participants were 25 men and 25 women American Indians without diabetes (Age: 20-34 years) in Phoenix, Arizona, USA. We assessed steps/day during 7 days of free living, simultaneously with three different monitors (Accusplit-AX120, MTI-ActiGraph, and Dynastream-AMP). We assessed total physical activity during free-living with doubly labeled water combined with resting metabolic rate measured by expired gas indirect calorimetry. Glucose tolerance was determined during an oral glucose tolerance test.

Findings: Based on observed counts in the laboratory, the AMP was the most accurate device, followed by the MTI and the AX120, respectively. The estimated energy cost of 1000 steps per day was lower in the AX120 than the MTI or AMP. The correlation between AX120-assessed steps/day and waist circumference was significantly higher than the correlation between AMP steps and waist circumference. The difference in steps per day between the AX120 and both the AMP and the MTI were significantly related to waist circumference.

Interpretation: Between-monitor differences in step counts influence the observed relationship between walking and obesity-related traits.

Downloads
PDF (281.7 KB)
Download count: 2

Details

Title
  • Between-Monitor Differences in Step Counts Are Related to Body Size: Implications for Objective Physical Activity Measurement
Date Created
2011-04-27
Resource Type
  • Text
  • Collections this item is in
    Identifier
    • Digital object identifier: 10.1371/journal.pone.0018942
    • Identifier Type
      International standard serial number
      Identifier Value
      1045-3830
    • Identifier Type
      International standard serial number
      Identifier Value
      1939-1560
    Note
    • The article is published at http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0018942

    Citation and reuse

    Cite this item

    This is a suggested citation. Consult the appropriate style guide for specific citation guidelines.

    Pomeroy, J., Brage, S., Curtis, J. M., Swan, P. D., Knowler, W. C., & Franks, P. W. (2011). Between-Monitor Differences in Step Counts Are Related to Body Size: Implications for Objective Physical Activity Measurement. PLoS ONE, 6(4). doi:10.1371/journal.pone.0018942

    Machine-readable links