Printed passive microfluidic devices using TEOS reactive inks

154713-Thumbnail Image.png
Description
This paper details ink chemistries and processes to fabricate passive microfluidic devices using drop-on-demand printing of tetraethyl-orthosilicate (TEOS) inks. Parameters space investigation of the relationship between printed morphology and ink chemistries and printing parameters was conducted to demonstrate that

This paper details ink chemistries and processes to fabricate passive microfluidic devices using drop-on-demand printing of tetraethyl-orthosilicate (TEOS) inks. Parameters space investigation of the relationship between printed morphology and ink chemistries and printing parameters was conducted to demonstrate that morphology can be controlled by adjusting solvents selection, TEOS concentration, substrate temperature, and hydrolysis time. Optical microscope and scanning electron microscope images were gathered to observe printed morphology and optical videos were taken to quantify the impact of morphology on fluid flow rates. The microscopy images show that by controlling the hydrolysis time of TEOS, dilution solvents and the printing temperature, dense or fracture structure can be obtained. Fracture structures are used as passive fluidic device due to strong capillary action in cracks. At last, flow rate of passive fluidic devices with different thickness printed at different temperatures are measured and compared. The result shows the flow rate increases with the increase of device width and thickness. By controlling the morphology and dimensions of printed structure, passive microfluidic devices with designed flow rate and low fluorescence background are able to be printed.
Date Created
2016
Agent

Development of breathable, self-sealing protective garment

154474-Thumbnail Image.png
Description
“Smart” materials are used for a broad range of application including electronics, bio-medical devices, and smart clothing. This work focuses on development of smart self-sealing and breathable protective gear for soldiers against Chemical Weapon Agents (CWA). Specifically, the response of

“Smart” materials are used for a broad range of application including electronics, bio-medical devices, and smart clothing. This work focuses on development of smart self-sealing and breathable protective gear for soldiers against Chemical Weapon Agents (CWA). Specifically, the response of chemo-mechanical swelling polymer modified meshes to contact with stimuli droplets was studied. Theoretical discussion of the mechanism of smart materials is followed by development and experimental analysis of different modified mesh designs. A multi-physics model is proposed based on experimental data and the prototype of the fabric is tested in aerosol impingement conditions to confirm the barrier formed by rapid-self-sealing feature of the design.
Date Created
2016
Agent

Conformable skin electronics based on spiral pattern

153573-Thumbnail Image.png
Description
Skin electronics is one of the most promising applications of stretchable electronics. The versatility of skin electronics can only be guaranteed when it has conformal contact with human skin. While both analytical and numerical solutions for contact between serpentine interconnects

Skin electronics is one of the most promising applications of stretchable electronics. The versatility of skin electronics can only be guaranteed when it has conformal contact with human skin. While both analytical and numerical solutions for contact between serpentine interconnects and soft substrate remain unreported, the motivation of this thesis is to render a novel method to numerically study the conformability of the serpentine interconnects. This thesis explained thoroughly how to conduct finite element analysis for the conformability of skin electronics, including modeling, meshing method and step setup etc.. User-defined elements were implemented to the finite element commercial package ABAQUS for the analysis of conformability. With thorough investigation into the conformability of Fermat’s spiral, it has been found that the kirigami based pattern exhibits high conformability. Since thickness is a key factor to design skin electronics, the thesis also talked about how the change of thickness of the skin electronics impacts on the conformability.
Date Created
2015
Agent

Gallium-based room temperature liquid metals and its application to single channel two-liquid hyperelastic capacitive strain sensors

153411-Thumbnail Image.png
Description
Gallium-based liquid metals are of interest for a variety of applications including flexible electronics, soft robotics, and biomedical devices. Still, nano- to microscale device fabrication with these materials is challenging because of their strong adhesion to a majority of substrates.

Gallium-based liquid metals are of interest for a variety of applications including flexible electronics, soft robotics, and biomedical devices. Still, nano- to microscale device fabrication with these materials is challenging because of their strong adhesion to a majority of substrates. This unusual high adhesion is attributed to the formation of a thin oxide shell; however, its role in the adhesion process has not yet been established. In the first part of the thesis, we described a multiscale study aiming at understanding the fundamental mechanisms governing wetting and adhesion of gallium-based liquid metals. In particular, macroscale dynamic contact angle measurements were coupled with Scanning Electron Microscope (SEM) imaging to relate macroscopic drop adhesion to morphology of the liquid metal-surface interface. In addition, room temperature liquid-metal microfluidic devices are also attractive systems for hyperelastic strain sensing. Currently two types of liquid metal-based strain sensors exist for inplane measurements: single-microchannel resistive and two-microchannel capacitive devices. However, with a winding serpentine channel geometry, these sensors typically have a footprint of about a square centimeter, limiting the number of sensors that can be embedded into. In the second part of the thesis, firstly, simulations and an experimental setup consisting of two GaInSn filled tubes submerged within a dielectric liquid bath are used to quantify the effects of the cylindrical electrode geometry including diameter, spacing, and meniscus shape as well as dielectric constant of the insulating liquid and the presence of tubing on the overall system's capacitance. Furthermore, a procedure for fabricating the two-liquid capacitor within a single straight polydiemethylsiloxane channel is developed. Lastly, capacitance and response of this compact device to strain and operational issues arising from complex hydrodynamics near liquid-liquid and liquid-elastomer interfaces are described.
Date Created
2015
Agent