A Heterogeneous Porous Media Model for Fluid Flow Simulation
Description
Owing to the surge in development of endovascular devices such as coils and flow diverter stents, doctors are inclined to approach surgical cases non-invasively more often than before. Treating brain aneurysms as a bulging of a weakened area of a blood vessel is no exception. Therefore, promoting techniques that can help surgeons have a better idea of treatment outcomes are of invaluable importance.
In order to investigate the effects of these devices on intra-aneurysmal hemodynamics, the conventional computational fluid dynamics (CFD) approach uses the explicit geometry of the device within an aneurysm and discretizes the fluid domain to solve the Navier-Stokes equations. However, since the devices are made of small struts, the number of mesh elements in the boundary layer region would be considerable. This cumbersome task led to the implementation of the porous medium assumption. In this approach, the explicit geometry of the device is eliminated, and relevant porous medium assumptions are applied. Unfortunately, as it will be shown in this research, some of the porous medium approaches used in the literature are over-simplified. For example, considering the porous domain to be homogeneous is one major drawback which leads to significant errors in capturing the intra-aneurysmal flow features. Specifically, since the devices must comply with the complex geometry of an aneurysm, the homogeneity assumption is not valid.
In this research, a novel heterogeneous porous medium approach is introduced. This results in a substantial reduction in the total number of mesh elements required to discretize the flow domain while not sacrificing the accuracy of the method by over-simplifying the utilized assumptions.
In order to investigate the effects of these devices on intra-aneurysmal hemodynamics, the conventional computational fluid dynamics (CFD) approach uses the explicit geometry of the device within an aneurysm and discretizes the fluid domain to solve the Navier-Stokes equations. However, since the devices are made of small struts, the number of mesh elements in the boundary layer region would be considerable. This cumbersome task led to the implementation of the porous medium assumption. In this approach, the explicit geometry of the device is eliminated, and relevant porous medium assumptions are applied. Unfortunately, as it will be shown in this research, some of the porous medium approaches used in the literature are over-simplified. For example, considering the porous domain to be homogeneous is one major drawback which leads to significant errors in capturing the intra-aneurysmal flow features. Specifically, since the devices must comply with the complex geometry of an aneurysm, the homogeneity assumption is not valid.
In this research, a novel heterogeneous porous medium approach is introduced. This results in a substantial reduction in the total number of mesh elements required to discretize the flow domain while not sacrificing the accuracy of the method by over-simplifying the utilized assumptions.
Date Created
2018
Contributors
- Yadollahi Farsani, Hooman (Author)
- Herrmann, Marcus (Thesis advisor)
- Frakes, David (Thesis advisor)
- Chong, Brian (Committee member)
- Peet, Yulia (Committee member)
- Oswald, Jay (Committee member)
- Arizona State University (Publisher)
Topical Subject
Resource Type
Extent
110 pages
Language
eng
Copyright Statement
In Copyright
Primary Member of
Peer-reviewed
No
Open Access
No
Handle
https://hdl.handle.net/2286/R.I.51575
Level of coding
minimal
Note
Doctoral Dissertation Mechanical Engineering 2018
System Created
- 2019-02-01 07:00:42
System Modified
- 2021-08-26 09:47:01
- 3 years 2 months ago
Additional Formats