Full metadata
Title
Modeling, experimentation, and analysis of data center waste heat recovery and utilization
Description
Increasing computational demands in data centers require facilities to operate at higher ambient temperatures and at higher power densities. Conventionally, data centers are cooled with electrically-driven vapor-compressor equipment. This paper proposes an alternative data center cooling architecture that is heat-driven. The source is heat produced by the computer equipment. This dissertation details experiments investigating the quantity and quality of heat that can be captured from a liquid-cooled microprocessor on a computer server blade from a data center. The experiments involve four liquid-cooling setups and associated heat-extraction, including a radical approach using mineral oil. The trials examine the feasibility of using the thermal energy from a CPU to drive a cooling process. Uniquely, the investigation establishes an interesting and useful relationship simultaneously among CPU temperatures, power, and utilization levels. In response to the system data, this project explores the heat, temperature and power effects of adding insulation, varying water flow, CPU loading, and varying the cold plate-to-CPU clamping pressure. The idea is to provide an optimal and steady range of temperatures necessary for a chiller to operate. Results indicate an increasing relationship among CPU temperature, power and utilization. Since the dissipated heat can be captured and removed from the system for reuse elsewhere, the need for electricity-consuming computer fans is eliminated. Thermocouple readings of CPU temperatures as high as 93°C and a calculated CPU thermal energy up to 67Wth show a sufficiently high temperature and thermal energy to serve as the input temperature and heat medium input to an absorption chiller. This dissertation performs a detailed analysis of the exergy of a processor and determines the maximum amount of energy utilizable for work. Exergy as a source of realizable work is separated into its two contributing constituents: thermal exergy and informational exergy. The informational exergy is that usable form of work contained within the most fundamental unit of information output by a switching device within a CPU. Exergetic thermal, informational and efficiency values are calculated and plotted for our particular CPU, showing how the datasheet standards compare with experimental values. The dissertation concludes with a discussion of the work's significance.
Date Created
2014
Contributors
- Haywood, Anna (Author)
- Phelan, Patrick E (Thesis advisor)
- Herrmann, Marcus (Committee member)
- Gupta, Sandeep (Committee member)
- Trimble, Steve (Committee member)
- Myhajlenko, Stefan (Committee member)
- Arizona State University (Publisher)
Topical Subject
Extent
xvi, 130 p. : col. ill
Language
eng
Copyright Statement
In Copyright
Primary Member of
Peer-reviewed
No
Open Access
No
Handle
https://hdl.handle.net/2286/R.I.25003
Statement of Responsibility
by Anna Haywood
Description Source
Viewed on Aug. 11, 2014
Level of coding
full
Note
thesis
Partial requirement for: Ph.D., Arizona State University, 2014
bibliography
Includes bibliographical references (p. 120-128)
Field of study: Mechanical engineering
System Created
- 2014-06-09 02:12:01
System Modified
- 2021-08-26 09:47:01
- 3 years 3 months ago
Additional Formats