Radiation dose optimization for critical organs
Description
Ionizing radiation used in the patient diagnosis or therapy has negative effects on the patient body in short term and long term depending on the amount of exposure. More than 700,000 examinations are everyday performed on Interventional Radiology modalities [1], however; there is no patient-centric information available to the patient or the Quality Assurance for the amount of organ dose received. In this study, we are exploring the methodologies to systematically reduce the absorbed radiation dose in the Fluoroscopically Guided Interventional Radiology procedures. In the first part of this study, we developed a mathematical model which determines a set of geometry settings for the equipment and a level for the energy during a patient exam. The goal is to minimize the amount of absorbed dose in the critical organs while maintaining image quality required for the diagnosis. The model is a large-scale mixed integer program. We performed polyhedral analysis and derived several sets of strong inequalities to improve the computational speed and quality of the solution. Results present the amount of absorbed dose in the critical organ can be reduced up to 99% for a specific set of angles. In the second part, we apply an approximate gradient method to simultaneously optimize angle and table location while minimizing dose in the critical organs with respect to the image quality. In each iteration, we solve a sub-problem as a MIP to determine the radiation field size and corresponding X-ray tube energy. In the computational experiments, results show further reduction (up to 80%) of the absorbed dose in compare with previous method. Last, there are uncertainties in the medical procedures resulting imprecision of the absorbed dose. We propose a robust formulation to hedge from the worst case absorbed dose while ensuring feasibility. In this part, we investigate a robust approach for the organ motions within a radiology procedure. We minimize the absorbed dose for the critical organs across all input data scenarios which are corresponding to the positioning and size of the organs. The computational results indicate up to 26% increase in the absorbed dose calculated for the robust approach which ensures the feasibility across scenarios.
Date Created
2013
Contributors
- Khodadadegan, Yasaman (Author)
- Zhang, Muhong (Thesis advisor)
- Pavlicek, William (Thesis advisor)
- Fowler, John (Committee member)
- Wu, Tong (Committee member)
- Arizona State University (Publisher)
Topical Subject
Resource Type
Extent
x, 109 p. : Ill. (some col.)
Language
eng
Copyright Statement
In Copyright
Primary Member of
Peer-reviewed
No
Open Access
No
Handle
https://hdl.handle.net/2286/R.I.17873
Statement of Responsibility
by Yasaman Khodadadegan
Description Source
Viewed on Dec. 4, 2013
Level of coding
full
Note
thesis
Partial requirement for: Ph.D., Arizona State University, 2013
bibliography
Includes bibliographical references (p. 100-107)
Field of study: Industrial engineering
System Created
- 2013-07-12 06:21:24
System Modified
- 2021-08-30 01:41:58
- 3 years 2 months ago
Additional Formats